Draining a tank is only a division sum when the flow is constant. A pump or a metered outlet can be treated that way, but a gravity outlet slows down as the water level falls: the driving head shrinks, so the last litres take noticeably longer than the first.
This tool offers both methods. Use the steady-flow mode for pumped drainage or a measured rate, and the gravity mode for a sharp-edged hole or short pipe stub in a vertical-sided tank. The gravity result is a best-case estimate — real valves, bends and hoses add friction and extend the time.
Calculator
How to use this calculator
- Enter the tank volume and unit. If the tank is not full, set the drain-from percentage to the starting fill level.
- For a pumped outlet or a measured flow, keep the steady-flow tab and enter the rate in any supported unit. The optional pipe diameter only shows a theoretical reference flow.
- For a gravity outlet, switch to the gravity tab. Enter the depth of water above the outlet when full, the outlet internal diameter and the outlet type.
- Read the result. Gravity drainage assumes a vertical-sided tank and drains down to the outlet; add extra time in practice for valves, elbows and hoses.
The formula
Steady flow: t = V ÷ QGravity: Q = Cd × A × √(2gh)t = (Atank ÷ (Cd × A)) × √(2h₁ ÷ g)Atank = volume ÷ full depth · A = π(d ÷ 2)²Cd = 0.61 sharp-edged hole, 0.82 short pipe stub; g = 9.80665 m/s².
Variables
| Symbol | Meaning | Unit | Note |
|---|---|---|---|
V | Volume to drain | L | Total capacity multiplied by the drain-from percentage. |
Q | Steady flow rate | L/min | Measured pump or outlet discharge. |
Cd | Discharge coefficient | — | 0.61 for a sharp edge, 0.82 for a short stub. |
A | Outlet area | m² | Computed from the internal diameter. |
h₁ | Starting head | m | Water depth above the outlet at the selected fill level. |
g | Gravity | m/s² | Standard 9.80665 m/s². |
Torricelli gravity-drain estimate
Outlet velocity follows v = √(2gh), so flow falls as the square root of the remaining head. Integrating that relationship for a constant cross-section tank gives the time formula used here. A useful rule of thumb: gravity emptying takes about twice as long as dividing the volume by the initial flow rate, because the flow is continuously decreasing.
The model is limited to straight-sided tanks. Conical, spherical and horizontal cylindrical vessels change cross-section with depth and need a different integration.
Flow unit conversion reference
| Unit | L/min |
|---|---|
| Litre per second | 60 |
| Litre per hour | 0.01667 |
| m³ per hour | 16.667 |
| US gal per minute | 3.7854 |
| US gal per hour | 0.0631 |
Why real drainage is slower
A long pipe adds friction that this simple orifice model ignores, and every elbow, valve and flexible hose costs more head. Sediment can partly block the outlet, and a vortex can reduce discharge as the level drops. Treat the gravity estimate as the fastest plausible time, then confirm with a timed measurement if the drain-down window matters.
Worked example
A vertical-sided 1,000 L tank, 1.0 m of water above a 25 mm sharp-edged outlet, Cd 0.61.
- Footprint = 1,000 L ÷ 1,000 ÷ 1.0 m = 1.0 m².
- Outlet area = π × (0.025 ÷ 2)² = 0.000491 m².
- Starting flow = 0.61 × 0.000491 × √(2 × 9.81 × 1.0) ≈ 0.00133 m³/s ≈ 79.6 L/min.
- Drain time = (1.0 ÷ (0.61 × 0.000491)) × √(2 × 1.0 ÷ 9.81) ≈ 1,508 s ≈ 25.1 min.
- Dividing by the initial flow alone would give only about 12.6 min — roughly half the true time.
Result: About 25 minutes by gravity; roughly twice the naive estimate from the starting flow.
Frequently asked questions
How do I calculate how long it takes to drain a tank?
For a steady flow, divide the volume to be drained by the flow rate. For a gravity outlet, use the Torricelli integration, because the flow falls as the water level drops.
Why does draining take longer in practice?
Valves, elbows, hoses and partially blocked outlets all add friction. The gravity calculation also assumes a straight-sided tank and clean water.
How can I find my outlet flow rate?
Time how long it takes to fill a known bucket, read the pump curve, or use a clamp-on ultrasonic flow meter on the outlet pipe.
What flow should a 25 mm household tank outlet give?
In theory a sharp-edged 25 mm hole under 2 m of head starts near 112 L/min. Real systems are much lower once pipe friction and fittings are included.
How long does a 1,000-litre tank take to drain?
At a steady 40 L/min, about 25 minutes. Under gravity through a 25 mm outlet with 1 m head, also about 25 minutes for a 1 m² footprint tank.
Can I calculate a partially filled tank?
Yes. Set the drain-from percentage to the current fill level; in gravity mode that percentage sets the starting head.
What pipe diameter do I need for a target drain time?
For gravity drainage, time scales roughly with the inverse square of diameter, so doubling the diameter cuts the time to about a quarter. For pumped drainage, work out the required flow and use a pipe-flow calculator.
Sources and verification
- US Bureau of Reclamation — Water Measurement Manual, Chapter 9 — Orifice flow depends on head and outlet construction.
- NIST Guide to the SI — Standard gravity and volume conversion definitions.
- USGS Water Science School — Background on discharge and water measurement.
Formula verification uses published references and hand-checked examples. We do not claim a named professional has reviewed this page; the method and sources are published instead.
Results are estimates for general information, based on standard geometry, hydraulics and published reference values. They are not engineering, medical, legal or professional advice. Verify critical calculations with a qualified professional and check local requirements.
Keep calculating
Tank Refill Time Calculator
Work out how long a tank takes to fill from its volume and the net flow arriving at it.
Water Flow Rate Calculator
Convert pipe diameter and velocity — or a timed volume — into flow in nine common units.
Pipe Size Flow Rate Calculator
Estimate the flow a pipe can carry from its bore, length, available pressure and material.
Pump Horsepower Flow Rate Calculator
Convert pump power, flow and head in either direction, with efficiency and a standard motor size.