Refill, Flow & Time

Pump Horsepower Flow Rate Calculator

A pump converts shaft power into water horsepower: the product of flow, head and specific gravity divided by a constant. Real pumps need more shaft power than the theoretical minimum because of efficiency losses, and the motor must be chosen from a standard rating above that requirement.

This calculator works in three directions. Enter flow and head to find the required brake horsepower, or enter motor power and head to find the achievable flow, or enter power and flow to find the achievable head. Each mode shares the same efficiency and fluid-density inputs, so the results stay consistent.

Calculator

How to use this calculator

  1. Choose what you want to solve: horsepower from flow and head, flow from power and head, or head from power and flow.
  2. Enter flow and total dynamic head for the horsepower mode. Total head includes static lift, pipe friction and any required outlet pressure, not just the vertical height.
  3. If your head is given as pressure, select psi or bar: the calculator converts it to an equivalent column of the fluid using specific gravity.
  4. Set the pump efficiency from the manufacturer curve where possible. Read the result and, in horsepower mode, the next standard motor size with roughly 10% margin.

The formula

WHP = GPM × head(ft) × SG ÷ 3960
BHP = WHP ÷ η
GPM = BHP × η × 3960 ÷ (head(ft) × SG)
head(ft) = BHP × η × 3960 ÷ (GPM × SG)
kW = BHP × 0.745699872

Variables

SymbolMeaningUnitNote
GPMFlow rategal/minConverted from L/min, L/hr or m³/hour.
headTotal dynamic headftConverted from metres, psi or bar.
SGSpecific gravity—1.00 for water at ordinary temperature.
ηPump efficiency—Fraction, from 10% to 99% in the input.
WHPWater horsepower—Power delivered to the water.
BHPBrake horsepower—Power required at the pump shaft.

Understanding water and brake horsepower

Water horsepower is the theoretical power needed to move a given flow against a given head. Brake horsepower is what the shaft must actually deliver, equal to water horsepower divided by pump efficiency. At 70% efficiency the shaft needs about 43% more power than the ideal value.

The constant 3960 comes from 33,000 foot-pounds per minute divided by roughly 8.33 pounds per US gallon.

Typical pump power by application

ApplicationFlowHeadMotor
Rooftop tank fill10–25 L/min8–15 m0.25–0.5 HP
Apartment supply30–80 L/min12–20 m0.5–1.5 HP
Deep borehole10–50 L/min30–120 m0.5–3 HP
Pool circulation100–300 L/min10–25 m1–3 HP
Irrigation200–2,000 L/min15–50 m2–30 HP
Fire pumps500–2,000 L/min30–80 m10–75 HP

Fire pumps follow separate standards and are not sized by this general table.

Always size up

Select the next standard motor above the calculated brake horsepower with roughly 10–20% margin, and check the pump curve at its worst-power point: for a centrifugal pump, power can rise as head falls. Electrical input is higher again, because the motor itself has efficiency losses. None of this replaces NPSH checks or a proper pump selection.

Worked example

Size a motor for 50 US GPM at 100 ft total head, water at SG 1.00 and 70% pump efficiency.

  1. Water horsepower = 50 × 100 × 1.00 ÷ 3960 = 1.26 HP.
  2. Brake horsepower = 1.26 ÷ 0.70 ≈ 1.80 HP, or 1.80 × 0.7457 ≈ 1.34 kW at the shaft.
  3. Apply a 10% margin: 1.80 × 1.10 = 1.98 HP, so choose a 2 HP motor.
  4. With a motor efficiency near 85%, electrical input ≈ 1.34 ÷ 0.85 ≈ 1.6 kW.
  5. Metric check: 189 L/min at 30.5 m gives about 0.94 kW of water power, the same 1.26 HP.

Result: 1.80 HP brake power at the shaft; select a 2 HP standard motor for the 10% margin.

Frequently asked questions

How do I calculate pump horsepower from flow and head?

Water horsepower is GPM × head in feet × specific gravity ÷ 3960. Divide by pump efficiency to get brake horsepower at the shaft.

What is the difference between water and brake horsepower?

Water horsepower is the ideal power delivered to the liquid. Brake horsepower includes pump losses; at 70% efficiency it is about 43% higher.

What efficiency should I use?

Small domestic pumps are often 40–55%, while larger centrifugal pumps near their best efficiency point reach 60–80%. Use the manufacturer curve if available.

How do I convert pump horsepower to kilowatts?

Multiply horsepower by 0.745699872. One kilowatt is about 1.341 horsepower.

What flow do I need to fill a 1,000-litre tank in 30 minutes?

About 33 L/min, roughly 8.8 GPM. At 10 m head the water power is tiny; after friction and a low-efficiency small pump, a 0.25 HP motor is usually enough.

Does pipe friction change the horsepower I need?

Yes. Total dynamic head includes friction. A rough allowance is 20–30% above static lift, but a Hazen-Williams or Darcy-Weisbach calculation is better.

What size pump do I need for a rooftop tank?

For three floors, allow about 12 m static lift plus 3 m of friction. At 20 L/min the water power is around 50 W; with 65% efficiency a 0.25 HP motor covers it, provided its curve delivers 20 L/min at 15 m.

Sources and verification

Formula verification uses published references and hand-checked examples. We do not claim a named professional has reviewed this page; the method and sources are published instead.

Results are estimates for general information, based on standard geometry, hydraulics and published reference values. They are not engineering, medical, legal or professional advice. Verify critical calculations with a qualified professional and check local requirements.