Agricultural & Irrigation
Drip Irrigation Tank Size Calculator
A drip system does not need a tank sized from evapotranspiration alone; its demand is set by hardware. Multiply the number of emitters by their flow and the hours you run them, and you have a daily volume. Multiply that by the number of days you want to get through without a refill and you have a minimum storage figure.
This calculator works from those hardware parameters and adds a practical purchase recommendation: 15% headroom rounded up to a common tank size. It also checks the resulting application depth against typical crop water use, so an overscheduled system is flagged rather than quietly turned into a very large tank.
Calculator
How to use this calculator
- Choose a crop preset if you want typical planting density and emitter settings as a starting point, then adjust the fields below to your actual system.
- Enter the number of plants or trees and the emitters per plant. If you know the area, add it as well so the tool can check the application depth.
- Set the flow per emitter and its unit. Common drip emitters deliver 2, 4 or 8 L/hr; gallons per hour are converted automatically.
- Enter daily run hours and the number of zones that run one at a time, then choose a buffer from 1 to 14 days.
- Read the minimum storage and the suggested tank to buy. Check the depth note: most crops use roughly 4–9 mm/day from drip in hot weather.
The formula
Total emitters = plants × emitters per plantFlow (L/hr) = total emitters × flow per emitterDaily demand (L) = total flow × hours per dayMinimum tank (L) = daily demand × buffer daysSuggested buy = tank × 1.15, rounded up to 250 / 500 / 1,000 / 5,000 LVariables
| Symbol | Meaning | Unit | Note |
|---|---|---|---|
n | Number of plants or trees | — | Enter the count actually irrigated in one run. |
e | Emitters per plant | — | Two or four is common for trees; one for row vegetables. |
q | Flow per emitter | L/hr or gal/hr | From the emitter specification or a measurement. |
t | Daily run hours | hr/day | Per zone; the tool totals all zones. |
b | Buffer days | days | Days of supply without any refill. |
Crop water requirement reference
Peak need per plant uses area × Kc × 6 mm ÷ 0.90, where 6 mm/day is a FAO-style hot-weather ETo and 0.90 is typical drip efficiency. Kc values are FAO-56 mid-season values. These are planning values, not measured demand.
| Crop | Spacing basis | Kc mid | Emitters | L/hr each | Peak need (L/plant/day) |
|---|---|---|---|---|---|
| Tomato (1.5 × 0.5 m) | 0.75 m²/plant | 1.15 | 1 | 2 | 5.8 |
| Bell pepper (1.5 × 0.4 m) | 0.6 m²/plant | 1.05 | 1 | 2 | 4.2 |
| Strawberry (≈0.25 m²/plant) | 0.25 m²/plant | 0.85 | 1 | 1 | 1.4 |
| Table grapes (3 × 1.5 m) | 4.5 m²/plant | 0.85 | 2 | 4 | 25.5 |
| Citrus, mature (6 × 4 m) | 24 m²/plant | 0.65 | 4 | 8 | 104 |
| Avocado, mature (8 × 6 m) | 48 m²/plant | 0.85 | 6 | 8 | 272 |
| Sugarcane | per metre of row | 1.25 | — | — | 12.5 L/m row |
Checking your schedule against crop water use
One litre applied over one square metre is one millimetre of depth. Divide daily litres by irrigated area to get an application depth. Below about 1.5 mm/day the schedule is very light; 4–9 mm/day is a normal range for drip in hot weather; above 12 mm/day you are exceeding the peak use of almost any crop. An oversized schedule does not help the crop — it just enlarges the tank and risks runoff.
Unit conversions and purchase sizing
1 US gal = 3.785411784 L, 1 Imperial gal = 4.54609 L, 1 acre = 4,046.86 m² and 1 ft² = 0.09290304 m². The 15% headroom and the 250/500/1,000/5,000 L rounding steps are an engineering convention, not a published standard. Always round up: running a head tank dry lets air and sediment into the emitters.
Worked example
One acre (4,047 m²) of tomatoes at 1.5 × 0.5 m spacing, irrigated from a well that may stop for three days.
- Plants: 4,047 ÷ 0.75 ≈ 5,400 plants.
- Water per plant: 0.75 × 1.15 × 6 ÷ 0.90 ≈ 5.8 L/day, so run time is about 5.8 ÷ (1 × 2) ≈ 3 hours.
- Daily demand: 5,400 × 1 emitter × 2 L/hr × 3 hr = 32,400 L/day.
- Depth check: 32,400 ÷ 4,047 ≈ 8.0 mm/day, within the normal hot-weather drip range.
- Storage: 32,400 × 3 days = 97,200 L; with 15% headroom and rounding, buy about 115,000 L (≈30,400 US gal).
Result: About 97,200 L minimum storage and a 115,000 L recommended tank. Running both zones at once would need roughly 10,800 L/hr (48 GPM); two alternating zones need about 5,400 L/hr (24 GPM) for six hours, with no change to tank size.
Frequently asked questions
How do I calculate the tank size for drip irrigation?
Multiply plants by emitters per plant, then by emitter flow and hours per day to get daily litres. Multiply by your buffer days, then add 15% and round up to a standard tank size.
What flow rate should I use for my drip emitters?
Common rates are 2, 4 and 8 L/hr. Use the rated flow on the emitter, and remember that pressure and filtration affect actual output.
How many buffer days should I plan for?
One to two days for a reliable mains supply, three to five for a single well or pump, and seven or more where power or supply is unreliable.
Can this be used for subsurface drip irrigation?
Yes. The storage calculation is the same because it depends on emitter hardware. subsurface design also needs attention to root intrusion and flushing, which this tool does not model.
How do I size a tank for one acre of drip tomatoes?
At 1.5 × 0.5 m spacing you have about 5,400 plants. Two-litre emitters run three hours a day give roughly 32,400 L/day, so three buffer days need about 97,000 L and you would buy around 115,000 L.
How much pressure does the tank need for drip irrigation?
Ten metres of water head is about 0.98 bar. Most emitters need 0.5–1.5 bar (pressure-compensating types 1.0–3.5 bar), so an elevated head tank or a pump is usually required.
Should I add extra capacity beyond the calculator result?
The recommendation already includes 15% and rounds up. Add more if you expect to expand the irrigated area or if refilling is genuinely unreliable.
Sources and verification
- FAO Irrigation and Drainage Paper No. 56 — Mid-season Kc values used in the crop reference table.
- FAO Training Manual No. 4: Irrigation Scheduling — Typical drip application efficiency of 90%.
- NIST Special Publication 811 — Gallon, acre and area conversion definitions.
Formula verification uses published references and hand-checked examples. We do not claim a named professional has reviewed this page; the method and sources are published instead.
Results are estimates for general information, based on standard geometry, hydraulics and published reference values. They are not engineering, medical, legal or professional advice. Verify critical calculations with a qualified professional and check local requirements.
Keep calculating
Irrigation Water Requirement Calculator
Work out net and gross irrigation water needs for any crop from area, ET₀, Kc and system efficiency.
Crop Water Need Calculator
Calculate crop evapotranspiration (ETc) by growth stage, with FAO-56 climate adjustment and irrigation need.
Farm Water Storage Calculator
Combine livestock drinking water and irrigation demand into a total farm storage tank recommendation.
Irrigation Pump Size Calculator
Size an irrigation pump from flow, total head and efficiency: hydraulic power, brake horsepower and motor.